| Budget Door Hold Open Magnets |
|---|

0501F-1B
Hold open s/s magnet & armature
Available surface or flush mount

0501F-1B
Surface mount s/s hold open magnet

FM1
Hold open magnet
Floor mount

WM1
Hold open magnet & armature
Wall mount

R40
Wall mount hold open magnet
White / brass finish
| Emergency breakglass units |
|---|

BG1 Green breakglass
BG2 Green breakglass - resettable
BG3 Double pole
BG4 Double pole - resettable

PS200
Tamper cover for breakglass

KG1
Replacement glass for BG1
| Keyswitches & Door Loops |
|---|

Keyswitches for single euro or oval cylinders. Available surface s/s mount with maintained or momentary microswitches.

SDL2
Surface door loop armoured

CDL1
Concealed door loop

9000DM/PTE Silver (press to exit)
9000DM Silver (no engraving)
Designed to release a fail safe locking device such as an electromagnetic lock. The standard bar length is 800mm which can be reduced to 650mm if required. The bar comes with a double pole microswitch and as an extra, can be engraved to your requirements.
| Other Accessories |
|---|
| PRODUCT CODE | DESCRIPTION | DETAILS | DIMENSIONS (mm) | |
|---|---|---|---|---|
![]() | BAT2.2AH | Battery back up | 12vdc 2.2amp hour (use two for 24vdc) | 175 x 30 x 60 |
![]() | BAT7AH | Battery back up | 12vdc 7amp hour (use two for 24vdc) | 150 x 60 x 65 |
![]() | VHR - AT182 |
Very handy Universal Relay |
Input 9.5V - 30V AC or DC Rated: | 52 x 48 x 27H |
![]() | INLT2 | LED Door Indicator | Stainless steel red/green LEDs | 85 x 85 x 39 |
![]() | 3E0610-1 | Surface housing for INLT2 | Stainless steel | 85 x 85 x 38 |
![]() | RELACDCT | Timer PCB 1 -60 seconds | 12-24vdc input Rated: 8A @ 24vdc | 45 x 70 x 20 |
![]() | TRMV1 | Timer PCB 4, 8, 12, 16, 20 & 24 minutes or seconds | 12-24vdc input. Rated: 8A @ 24vdc | 53 x 48 x 19 |
![]() | TDRM | Time delay relay module | Time delay 2 secs to 2 mins Time active 2 secs to 2 mins 10-28vdc Rated: 6A @ 24vdc | 84 x 52 x 19 |
![]() | TIM6DI | Central interlock interface board for up to 6 doors (6 x TIMV4) | 12-24vdc 80mA active current. One inhibit output per door accommodating up to 6 doors | 141 x 110 x 20 |
![]() | TIMV4 | Interlock and timer add-on interface board | 12-24vdc 80mA active current. Timer up to 2 mins Rated 8A @ 30vdc | 105 x 75 x 30 |
![]() | TIMHS | Two door interlock for controlling in and out access | 12-24vdc 80mA active current Rated 6A 24vdc Lock timer 5 or 10 secs | 178 x 122 x 36 |
![]() | ENC/LARGE | Large enclosure for PCB boards | Hinged metal box | 330 x 330 x 80 |
![]() | ENC/SMALL | Small enclosure for PCB boards | Hinged metal box | 250 x 225 x 80 |
![]() | TH827-12 | Digital timer | 12vdc weekly and daily digital time clock | 60 x 60 x 30 |